🎛️ Water Recapture Simulator
Model cooling technologies and municipal effluent integration
📊 Cooling Water Impact Benchmark
Gallons / Day Comparison🚰 Reclaimed Water Pipeline Capital Expenditure (CapEx) Schedule
Del Rio WWTP tertiary effluent purple-pipe extension routes, booster stations & TCEQ Chapter 210 permitting
| Candidate Parcel Corridor | WWTP Distance | Trenching & Pipe ($185/LF) | Booster Pump Lifts | TCEQ 210 Permitting | Total Pipeline CapEx | Developer Share (70%) | EDC / City Match (30%) |
|---|---|---|---|---|---|---|---|
| Site A: Del Rio Industrial Park (Farley Ln) | 3.4 km (11,155 LF) | $2.06M | 1 Station ($450k) | $85k | $2.99M | $2.09M | $897k |
| Site B: East US-90 Logistics Corridor | 9.2 km (30,184 LF) | $5.58M | 2 Stations ($900k) | $85k | $7.55M | $5.29M | $2.27M |
| Site C: North US-277 Energy Hub | 10.9 km (35,761 LF) | $6.62M | 2 Stations ($900k) | $85k | $8.74M | $6.12M | $2.62M |
| Site D: Ports-to-Plains Gateway (Spur 239) | 3.1 km (10,171 LF) | $1.88M | 1 Station ($450k) | $85k | $2.78M | $1.95M | $834k |
⚡ Electric Load & Transmission Parameters
AEP Texas & ERCOT Region📋 Interconnection Steps & Milestones
Fast-Track Queue⏳ ERCOT Large Load Interconnection & Substation MPT Procurement
PGRR115 energization risk bands and national transformer supply chain tracking
🛡️ Community Impact & Public Safety Guardrails
Acoustic decibel (dBA) attenuation and NFPA 855 BESS battery protocols
- Lithium Iron Phosphate (LiFePO4 / LFP): High thermal runaway resistance (>270°C).
- Continuous Multi-Gas Detection: Off-gas sensors monitor H2 and CO before runaway can initiate.
- Deflagration Relief & Water Deluge: NFPA 68 rooftop explosion venting and dry-pipe deluge curtain with 5" Storz Del Rio Fire Dept hookups.
- 10-Ft Enclosure Separation: Buffers between BESS units prevent cascading thermal propagation.
🎯 Del Rio EDC Target Partner Profiles
Data center operators and hyperscalers profiled by load, cooling tech, and Del Rio value fit
🏛️ Tax Abatement & Municipal Clawback Sandbox
15-year jurisdictional revenue modeling (City, County, SFDRCISD, Hospital) & breach penalty simulator
🏛️ Chapter 380 / Chapter 381 Incentive Architecture
Configure ad valorem abatements and JETI parameters
🛡️ Municipal Clawback Protection Stress-Tester
Configure agreement hurdle targets and simulate breach clawbacks
📈 15-Year Projected Tax Revenues by Jurisdictional Entity
Reflects 4-Year BPP Server Refresh Cycles| Year | Total Valuation | City Gross | City Abated (Ch. 380) | City Net Revenue | County Net Revenue | SFDRCISD Net Revenue | Total Combined Net |
|---|
🛡️ 5.2 STRESS TEST SCENARIO: Developer Default & Municipal Clawback Enforcement Schedule
Contractual performance hurdles vs simulated audit and enforceable statutory financial recapture ledger
Evaluates contractual non-performance ($110M / $200M CapEx delivered, 0.29 WUE, 21 FTEs) directly beneath standard accretion projections to demonstrate enforceable statutory clawbacks, liquidated damages, and legal remedies recapturing public abatements under Chapter 380/381 performance agreements.
| Negotiated Hurdle / Covenant | Contractual Target (Ceiling/Floor) | Simulated Performance Audit | Audit Status |
|---|
Simulated Default: Municipal Financial Recapture Breakdown
| Jurisdiction / Recapture Entity | Statutory Remedy / Mechanism | Financial Clawback Amount |
|---|
📄 Del Rio EDC Executive Feasibility Study Brief
Official policy recommendation document prepared for City Council & EDC Board